Field of view calculator
Use FOV calculator to compare lenses, sensor resolutions and camera positions. Calculate coverage and pixel size at your working distance.
| Camera info | Spatial resolution | Pixel size | Target coverage | Position | Alternative position |
|---|
Camera parameters are for reference only. Verify camera and lens specifications before making important decisions.
About the field of view calculator
Use the GRAYESS field of view calculator (FOV calculator) to plan coverage for thermal cameras and line scanners, compare fields of view and resolutions, and find suitable camera and scanner positions for industrial monitoring. See how working distance and device orientation affect the area covered and the size of each camera pixel or scanner sample on the target.
Select a camera or line scanner from our catalog, or choose "Custom camera" or "Custom line scanner" to specify your own parameters. Then adjust the camera angle, perpendicular distance to the target, and offset directly on the drawing. Camera angle changes the device's orientation, not its field of view.
Conventional cameras
The camera model assumes a rectilinear lens and evenly spaced detector pixels. It projects each pixel through the lens onto the target. With the camera facing the target straight on, pixel footprints are equal across the image; tilting the camera makes their sizes vary across the target.
Horizontal and vertical views use the corresponding lens angle and detector pixel count. Cameras with a single row of pixels use the same projection, but only the horizontal view is available.
Rotating-mirror line scanners
The scanner model assumes samples are evenly spaced by angle, rather than by position on an image sensor. Angular sample spacing is the full scan angle divided by the number of samples per full scan. Projecting this spacing onto a flat target gives larger sample footprints toward the edges, even when the scanner faces the target straight on.
The simplified sample size is the distance along the target between two rays separated by one angular sample interval. It describes the sampling geometry, not the optical spot size or the smallest feature the scanner can measure accurately. Only the scan direction is calculated; scan rate, target movement and resolution in the direction of travel are not modeled.
Reducing the working field of view crops the selected full scan. It uses fewer samples and preserves their angular spacing. It does not compress all samples into the smaller angle or improve resolution.
Hot spot check and limitations
Enable Hot spot and enter the smallest hot spot size you want to check, in millimeters (Metric) or inches (Imperial). Required pixels / samples sets how many local pixel or scanner sample footprints the hot spot should span in the calculated direction, from 1 to 4. This is a resolution requirement; target coverage describes the area a device sees. Red target markings show covered areas where no device meets the requirement. Areas outside every field of view are not marked.
This is a geometric planning estimate. A one-pixel or one-sample span does not guarantee detection, and meeting the selected requirement does not guarantee accurate temperature measurement. Lens distortion, optical spot size, focus, detector response and motion blur are not included. Verify the selected camera or scanner configuration and its measurement specifications before relying on the results.
Reading the results
The table shows the minimum to maximum pixel or sample size across each device's full field of view. Compact filled labels below the target show sizes at both side rays. Line scanners also show a dashed ray and the smallest sample size when the minimum lies inside the field of view and is smaller than both edge samples. Both device types use the same straight-line geometry for coverage, ray distances and positioning.
Spatial resolution is shown in milliradians. For cameras it is an average estimate, calculated as field of view divided by detector pixels. For scanners it is the angular sample spacing of the full scan. The target footprints also account for distance and device orientation.
Sharing
Click "Share" above the drawing to copy a link to your current setup. Send the link to someone else or keep it to reopen this drawing later. The link contains all camera and scanner values, positions, custom names and calculator settings. Anyone with the link can open the setup without an account.
Download SVG or JPG for the drawing with its comparison table, or CSV for the table values.
Camera and line scanner catalog
The calculator's catalog includes thermal cameras and industrial infrared line scanners from FLIR, Fluke, Optris, HIKMICRO, Jenoptik, AMETEK LAND and other manufacturers. Lens options are listed with each camera model for convenient selection.
Cameras
- FLIR thermal cameras: A5, A15, A35, A40, A50, A65, A70, A400, A500, A700, AX8, ThermoVision A20V I and ThermoVision A40M.
- Fluke thermal cameras: RSE300, RSE600, TV33, TV36, TV43 and TV46.
- Jenoptik thermal cameras: Blackbird precision VGA, Blackbird precision XGA, VarioCAM HD 1024, EVIDIR alpha 320, EVIDIR alpha 640, IR-TCM 384 and IR-TCM 640.
- Optris thermal cameras: PI 1M, PI 05M, PI 08M, PI 160, PI 400i/450i, PI 640i, Xi 1M, Xi 05M, Xi 80, Xi 320/410 MT, Xi 400, Xi 410 LT and Xi 440/640.
- HIKMICRO thermal cameras: HM-TD2A37T, HM-TD2A67H1, HM-TD2A67H2, HM-TD2A67T, HM-TD3028T, HM-TD3118T, QD610, QD1210, QF310 and QF610.
- Nippon Avionics thermal cameras: R450, R550 and TS610/620/630.
- DIAS thermal cameras: PYROLINE 128L, PYROLINE 256L, PYROVIEW 380L and PYROVIEW 640L.
Line scanners
- Fluke line scanners: MP150/300.
- Raytek line scanners: MP50.
- AMETEK LAND line scanners: LSP-HD.
Compare cameras and scanners side by side, try different positions, and check their combined coverage of the target. Enter a hot spot size and choose the required number of pixels or samples across it to see where none of the devices meets this resolution requirement within the covered area.
To suggest a model for the catalog or report an inaccuracy, please contact us.